beautypg.com

Configure:response, Configure]:cntime – GW Instek PEL-3000 Series Programming Manual User Manual

Page 48

background image

PEL-3000 Programming Manual

46

Example

:VDELay 1.5 ms
Sets the delay time to 1.5ms.
:VDELay 0.0015 s
Sets the delay time to 1.5ms.

Query example

:VDELay?
>0.0015
The delay time is 1.5ms.

:CONFigure:RESPonse

Set

Query

Description

Sets or queries the response speed. This is the
equivalent to the CC, CR and CP Mode.

Syntax

:CONFigure:RESPonse { | MINimum |
MAXimum }

Query Syntax

:CONFigure:RESPonse?

Parameter

0.1, 0.2, 0.5, 1.0 (for
CC ,CR or CP mode only)

MINimum

Minimum response
speed

MAXimum

Maximum response
speed

Return Parameter

0.1, 0.2, 0.5, 1.0

Example

:CONFigure:RESPonse MAX
Sets the response to the maximum.

Query example

:CONFigure:RESPonse?
>1.0
Returns the response.

[:CONFigure]:CNTime

Set

Query

Description

Turns the Count Time timer function on or off.

Syntax

[:CONFigure]:CNTime { |OFF | ON }

Query Syntax

[:CONFigure]:CNTime?