beautypg.com

Program:pftime, Program:stime – GW Instek PEL-3000 Series Programming Manual User Manual

Page 106

background image

PEL-3000 Programming Manual

104

Syntax

:PROGram:OFFTime {[s]|OFF}

Query Syntax

:PROGram:OFFTime?

Parameter

[s]

(0~60) Off-Time in
seconds

OFF

Turns the Off-Time off.

Return Parameter

Off-Time:
(a time of 0.0 is equivalent
to “OFF”)

Example

:PROGram:OFFTime 1
Sets the Off-Time to 1 second.

Query example

:PROGram:OFFTime?
>Off-Time:1.0
Returns the Off-Time (1 second).

:PROGram:PFTime

Set

Query

Description

Sets or queries the Pass/Fail-Time for the selected
step number.

Syntax

:PROGram:PFTime {[s]|OFF}

Query Syntax

:PROGram:PFTime?

Parameter

[s]

(0 ~ (On-time + Off time -

0.1)) (in seconds)

OFF

Turns the P/F-Time off.

Return Parameter

P/F-Time:

Example

:PROGram:PFTime 1
Sets the P/F-Time to 1 second.

Query example

:PROGram:PFTime?
> P/F-Time:0.0
Returns the P/F-Time (1 second).

:PROGram:STIMe

Set

Query

Description

Sets or queries the Short-Time for the selected step
number.