beautypg.com

Program:sequence:short:time, Program:sequence:mode – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 97

background image

COMMAND DETAILS

97

:PROGram:SEQuence:SHORt:TIME

Program Number
Specific

Description

Sets the short time (seconds) for the current
program sequence.

Syntax

:PROGram:SEQuence:SHORt:TIME [S]

Parameter

[S]

Short Time

0.0

0 seconds = OFF

0.1~60

0.1~60 seconds

0.1~60S

0.1~60 seconds

Example

:PROG:SEQ:SHOR:TIME
0.5

The short time for the
program sequence is set
to .5 seconds

Query Syntax

:PROGram:SEQuence:SHORt:TIME?

Return Parameter 1 unit = 1 second Short Time

0.0~60

Returns the short time for
the program sequence.

Query Example

:PROG:SEQ:SHOR:TIME?
5

The short time for the
program sequence is 5
seconds.

:PROGram:SEQuence:MODE

Program Number
Specific

Description

Sets the program sequence to Auto, Manual or
Skip mode.

Syntax

:PROGram:SEQuence:MODE {MANUAL|AUTO|SKIP}

Parameter

MANUAL

Manual mode: program
sequence is run manually

AUTO

Auto mode: program
sequence is run
automatically