beautypg.com

Configure:protection:voltage:state, Configure:protection:voltage:level – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 45

background image

COMMAND DETAILS

45

:CONFigure:PROTection:VOLTage:STATe

Channel Specific
Command

Description

Sets the voltage protection for the current/specific
channel on or off. The voltage protection can also
be cleared.

Syntax

:CONFigure:PROTection:VOLTage:STATe
{OFF|0|ON|1|CLEAR|2}

Parameter

CLEAR/2

Clear

OFF/0

Off

ON/1

On

Example

:CONF:PROT:VOLT:STAT 1

Turns on voltage
protection.

Query Syntax

: CONFigure:PROTection:VOLTage:STATe?

Return Parameter

Voltage Protection state

0

Off

1

On

2

Clear

Query Example

:CONF:PROT:VOLT:STAT?

0

Voltage protection is
currently off.

:CONFigure:PROTection:VOLTage:LEVel

Channel Specific
Command

Description

Sets the voltage protection level for the
current/specific channel. The level can be set to
any applicable level or to the channel
maximum/minimum.

Syntax

:CONFigure:PROTection:VOLTage:LEVel
[V]|MIN|MAX

Parameter

Voltage Protection Level

30

30 volts

30V

30 volts