PEL-2000 Programming Manual

60

:CURRent:STATic:LOW:RISE/FALL

Channel Specific
Command

Description

Sets the low range rising/falling slew rates.

Syntax

:CURRent:STATic:LOW:RISE/FALL [A/uS]

Parameter

[A/uS]

Slew Rate

RISE/FALL 0.078A/uS

Sets the rising/falling slew
rate to 0.078A/uS

RISE/FALL 1

Sets the rising/falling slew
rate to 1A/uS

RISE/FALL MIN

Sets to the slowest
rising/falling slew rate.

RISE/FALL MAX

Sets to the fastest
rising/falling slew rate.

Example

:CURR:STAT:LOW:RISE .001

Sets the rising slew rate
to 0.001A/uS.

Query Syntax

: CURRent:STATic:LOW:RISE/FALL? [MIN|MAX]

Return Parameter [MAX|MIN]

Slew rate

1 Unit=1 amp/uS

Returns the slew rate.

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:CURR:STAT:LOW:RISE?
MIN
0.078

For low range CC mode,
the Minimum value for
the rising slew rate is
0.078 A/uS for the
specific channel.