beautypg.com

Fetch:power, Fetch:status, Fetch:allvoltage – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 72

background image

PEL-2000 Programming Manual

72

:FETCh:POWer?

Channel Specific
Status Command

Description

This query returns the real-time power of the load
module input for the specific channel.

Syntax

:FETCh:CURRent?

Parameter

1 unit= 1 amp

1

1 amp

Query Example

:FETC:POW?
1.2

The specific channel is at
1.2 watts.

:FETCh:STATus?

Status Command

Description

This query returns the status of the load module.
The returned value is the bit weight of the Channel
Status Register. See page 162.

Syntax

:FETCh:STATus?

Parameter

Condition

Condition

1

OC

16

OT

2

OV

32

G/N

4

OP

64

UVP

8

RV

16-128

Not Used

Query Example

:FETC:STAT?
2

Over voltage (OV)
protection has been
triggered for the specific
channel.

:FETCh:ALLVoltage?

All Channel Status
Command

Description

This query returns the voltage values of all the
load modules/channels in order from 1-8(PEL-
2004)/1-4(PEL2002).

Syntax

:FETCh:ALLVoltage?