beautypg.com

Ocp:channel:last, Ocp:channel:step:time – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 90

background image

PEL-2000 Programming Manual

90

:OCP:CHANnel:LAST

Channel Specific
Command

Description

Queries or sets the current value for after the
DUT OCP protection has been activated.

Syntax

:OCP:CHANnel:LAST {[ A ] | MIN | MAX}

Parameter

[A]

The current value in Amps.

MAX

The maximum current value.

MIN

The minimum current value.

Example

:OCP:CHAN:LAST MAX

Set the current value to
the maximum value.

Query Syntax

:OCP:CHANnel:LAST?

Return Parameter

Returns the current value in Amps.

Query Example

:OCP:CHAN:LAST?
3.0

Returns the current
value.

:OCP:CHANnel:STEP:TIME

Channel Specific
Command

Description

Queries or sets how long the step time is for the
OCP Test Automation.

Syntax

:OCP:CHANnel:STEP:TIME {[ S ] | MIN | MAX}

Parameter

[S]

The step time in seconds
(50mS~1600S).

MAX

The maximum step time.

MIN

The minimum step time.

Example

:OCP:CHAN:STEP:TIME
MIN

Set the step time to the
maximum value.

Query Syntax

:OCP:CHANnel:STEP:TIME?

Return Parameter

Returns the step time in seconds.

Query Example

:OCP:CHAN:STEP:TIME?
10.0

Returns the step time.