PEL-2000 Programming Manual

112

L1/L2 MIN

Sets L1 or L2 to the
minimum level for the
specific channel.

L1/L2 MAX

Sets L1 or L2 to the
maximum level for the
specific channel.

Example

:RES:DYN:HIGH:L1 10

In high range CR
dynamic mode, Set L1
(level 1) to 10 ohms.

Query Syntax

:RESistance:DYNamic:HIGH:L1/L2? [MIN|MAX]

Return Parameter [MAX|MIN]

Resistance

1 unit= 1 ohm

Returns the resistance of
Level 1/ 2 (L1/L2).

Query Example

:RES:DYN:HIGH:L2? MAX
15000.0

Returns the maximum
resistance allowed for
the channel. (PEL-2020)

:RESistance:DYNamic:HIGH:RISE/FALL

Channel Specific
Command

Description

Sets the high range rising/falling slew rate for CR
dynamic mode for the specific channel.

Syntax

:RESistance:DYNamic:HIGH:RISE/FALL
[A/uS]

Parameter

[A/uS]

Slew Rate

RISE/FALL 0.8A/uS

Sets the rising/falling slew
rate to 0.8A/uS

RISE/FALL 1

Sets the rising/falling slew
rate to 1A/uS

RISE/FALL MIN

Sets to the slowest
rising/falling slew rate.

RISE/FALL MAX

Sets to the fastest
rising/falling slew rate.

Example

:RES:DYN:HIGH:RISE 1.1

Sets the rising slew rate
to 1.1A/uS.