Current:static:low:avalue/bvalue – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 59

background image

COMMAND DETAILS

59

:CURRent:STATic:LOW:AVALue/BVALue

Channel Specific
Command

Description

Sets the low range A/B Value for constant current
static mode.

Syntax

:CURRent:STATic:LOW:AVALue/BVALue [A]

Parameter

NRf+[A]

AVALue 1

Sets A Value to 1 Amp.
(Low range only)

BVALue 2

Sets B Value to 2 Amps.
(Low Range only)

AVALue 1A

Sets A Value to 1 Amp.
(Low range only)

AVALue MIN

Sets A Value to the
minimum level for the
specific channel.

AVALue MAX

Sets A Value to the
maximum Level for the
specific channel.

Example

:CURR:STAT:LOW:AVAL 1

Sets low range CC static
mode A Value to 1 amp.

Query Syntax

:CURRent:STATic:LOW:AVALue/BVALue? [MAX|MIN]

Return Parameter [MAX|MIN]

Current

1 unit = 1 amp

Returns the current of the
A or B Value.

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:CURR:STAT:LOW:BVAL?
MAX
2

Returns the maximum
current allowed for the
channel. (PEL-2020)