beautypg.com

Power:recall, Power:low:avalue/bvalue – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 137

background image

COMMAND DETAILS

137

Query Example

:POW:CURR?
7.0

Returns the current limit
for the specific channel.

:POWer:RECall

Channel Specific
Command

Description

Sets or queries whether A Value or B Value is the
currently active value in CP mode.

Syntax

:POWer:RECall A/0, B/1

Parameter

A/0, B/1

Value

A/0

A

B/1

B

Example

:POW:REC 1

Makes B Value the active
value.

Query Syntax

:POWer:RECall?

Return Parameter

Value

0

A

1

B

Query Example

:POW:REC?
0

A Value is active.

:POWer:LOW:AVALue/BVALue

Channel Specific
Command

Description

Sets the low range A/B Value for constant power
mode.

Syntax

:POWer:LOW:AVALue/BVALue [W]

Parameter

NRf+[W]

AVALue 1

Sets A Value to 1 watt.

BVALue 1W

Sets B Value to 1 watt.

AVALue MIN

Sets A Value to the
minimum level for the
specific channel.