PEL-2000 Programming Manual

154

Parameter

OFF/0

Off

ON/1

On

Example

:SEQ:END:LOAD 0

On End Load = Off.

Query Syntax

:SEQuence:END:LOAD?

Return Parameter

On End Load

0

Off

1

On

Query Example

:SEQ:END:LOAD?
1

On End Load is On.

:SEQuence:VOLTage:RANGe

Channel Specific
Command

Description

Sets the sequence CC voltage range.

Syntax

:SEQuence:VOLTage:RANGe [V]|L|H

Parameter

[ V] , L, H

Range

16

Low range*

80V

High range*

L

Low range

H

High range

*Load module dependent, PEL-2020 shown.

Example

:SEQ:VOLT:RANG L

Sets the range to Low for
the channel.

Query Syntax

:SEQuence:VOLTage:RANGe?

Return Parameter

Range

16

Low PEL-2020,2030,2040

125

Low PEL-2041

80

High PEL-2020,2030,2040

500

High PEL-2041