COMMAND DETAILS

131

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:VOLT:L1?
5
:VOLT:L1? MAX
81.6000

A Value is set to 5 volts.

Returns the maximum
settable voltage.

:VOLTage:RECall

Channel Specific
Command

Description

Sets or queries whether A Value or B Value is the
currently active value in CV mode.

Syntax

:VOLTage:RECall {A|0|B|1}

Parameter

A/0

A

B/1

B

Example

:VOLT:REC 1

Makes B Value the active
value.

Query Syntax

:VOLTage:RECall?

Return Parameter

Value

0

A

1

B

:VOLTage:AVALue/BVALue

Channel Specific
Command

Description

Sets the voltage of A Value or B Value in CV mode.

Syntax

:VOLTage:AVALue/BVALue [V]

Parameter

[V]

Voltage

10

10 volts

10V

10 volts

MIN

Sets the voltage to the
minimum value for the
channel