beautypg.com

Sequence:point:time – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 152

background image

PEL-2000 Programming Manual

152

1.2

1.2A/us

1.2 A/us

1.2A/us

MAX/MIN

Maximum or minimum
value.

Example

:SEQ:POIN:RISE .3 A

Sets the rising slew rate
to 0.3 A/us

:SEQ:POIN:FALL .4 A

Sets the falling slew rate
to 0.4 A/us

Query Syntax

:SEQuence:POINt::RISE/FALL? [MAX|MIN]

Return Parameter

Slew Rate

1 unit = 1 A/us

Returns the slew rate.

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:SEQ:POIN:RISE?
0.30000

Returns the rising slew
rate (0.3 A/us).

:SEQ:POIN:FALL?
0.40000

Returns the falling slew
rate (0.4 A/us).

:SEQuence:POINt:TIME

Channel Specific
Command

Description

Sets the duration time of the current point in
seconds.

Syntax

:SEQuence:POINt:TIME [S]|MIN|MAX

Parameter

Duration Time

0.0001~60000

0.0001~60,000.0 seconds

0.0001~60000S

0.0001~60,000.0 seconds

MIN

0.0001seconds

MAX

60,000 seconds

Example

:SEQ:POIN:TIME 10

Sets the point duration
time to 10 seconds.

Query Syntax

:SEQuence:POIN:TIME? [MAX|MIN]