background image

PEL-2000 Programming Manual

132

MAX

Sets the voltage to the
maximum value for the
channel

Example

:VOLT:AVAL 10V

Sets A Value to 10 volts
for the specific channel

:VOLT:BVAL MAX

Sets B Value to the
maximum allowed
voltage for the specific
channel. (single channel
only)

Query Syntax

:VOLTage:AVALue/BVALue? [MAX|MIN]

Return Parameter 1 unit = 1 volt

Voltage

10

Returns the voltage of the
specific channel.

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:VOLT:AVAL?
5
:VOLT:AVAL? MAX
81.6000

A Value is set to 5 volts.

Returns the maximum
settable voltage.

:VOLTage:CURRent

Channel Specific
Command

Description

Sets the current limit in CV mode.

Syntax

:VOLTage:CURRent [ A ]

Parameter

[ A ]

Current limit

1

1 Amp

1A

1 Amp

MIN

Sets the current limit to
the minimum value for the
channel