COMMAND DETAILS

43

Parameter

OLD/0

Old

UPDATED/1

Updated

Example

:CONF:LOAD OLD

Configuration type set as
OLD.

Query Syntax

:CONFigure:LOAD?

Return Parameter

Configuration type

0

Old

1

Updated

Query Example

:CONF:LOAD?
0

Sets the load module
selector configuration
type as OLD.

:CONFigure:PROTection:CURRent:STATe

Channel Specific
Command

Description

Sets the current protection for the specific channel
on or off. The current protection can also be
cleared.

Syntax

:CONFigure:PROTection:CURRent:STATe
{OFF|0|ON|1|CLEAR|2}

Parameter

CLEAR/2

Cleared

OFF/0

Off

ON/1

On

Example

:CONF:PROT:CURR:STAT 1

Turns on current protection.

Query Syntax

: CONFigure:PROTection:CURRent:STATe?

Return Parameter

Current Protection

0

Off

1

On

2

Clear

Query Example

:CONF:PROT:CURR:STAT?

1

Current protection is
turned on.