beautypg.com

Current:dynamic:high:rise/fall – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 68

background image

PEL-2000 Programming Manual

68

Syntax

:CURRent:DYNamic:HIGH:L1/L2 [A]

Parameter

NRf+[A]

L1 10

Sets L1 to 10 Amps. (High
range only)

L2 20

Sets L2 to 20 Amps. (High
Range only)

L1/L2 MIN

Sets L1 or L2 to the
minimum level for the
specific channel.

L1/L2 MAX

Sets L1 or L2 to the
maximum Level for the
specific channel.

Example

:CURR:DYN:HIGH:L1 10

In high range CC
dynamic mode, Set L1
(level 1) to 10 amps.

Query Syntax

:CURRent:DYNamic:HIGH:L1/L2? [MIN|MAX]

Return Parameter [MAX|MIN]

Return value

1 unit= 1 amp

Returns the current of
Level 1/ 2 (L1/L2).

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:CURR:DYN:HIGH:L2?
MAX
20.4000

Returns the maximum
current allowed for the
channel. (PEL-2020)

:CURRent:DYNamic:HIGH:RISE/FALL

Channel Specific
Command

Description

Sets the high range rising/falling slew rate for CC
dynamic mode for the specific channel.

Syntax

:CURRent:DYNamic:HIGH:RISE/FALL [A/uS]

Parameter

[A/uS]

Slew Rate

RISE/FALL 0.8A/uS

Sets the rising/falling slew
rate to 0.8A/uS