beautypg.com

Ocp test automation commands, Ocp:edit:channel – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 87

background image

COMMAND DETAILS

87

OCP Test Automation Commands

:OCP:EDIT:CHANnel? ................................................... 87

:OCP:CHANnel:RANGe ................................................. 88

:OCP:CHANnel:STARt ................................................... 88

:OCP:CHANnel:END ...................................................... 89

:OCP:CHANnel:STEP:CURRent .................................... 89

:OCP:CHANnel:LAST ..................................................... 90

:OCP:CHANnel:STEP:TIME .......................................... 90

:OCP:CHANnel:DELay ................................................... 91

:OCP:CHANnel:TRIGger ................................................ 91

:OCP:CHANnel:ACTive .................................................. 92

:OCP:STATus?................................................................. 92

:OCP:SAVE ...................................................................... 93

:OCP:RESult? .................................................................. 93

:OCP:RUN ....................................................................... 93

:OCP:EDIT:CHANnel?

Channel Specific
Command

Description

Sets or queries which channel is used to apply the
OCP Test Automation parameters. Also see page
92 for setting the active channel.

Syntax

:OCP:EDIT:CHANnel

Parameter

1-8

Example

:OCP:EDIT:CHAN 1

Sets channel 1 as the
chosen channel.

Query Syntax

:OCP:EDIT:CHANnel?

Return Parameter

1-8

Query Example

:OCP:EDIT:CHAN?
1

Channel 1 is the chosen
channel.