beautypg.com

GW Instek PEL-2000 Series Programming User Manual User Manual

Page 29

background image

COMMAND DETAILS

29

Query Example

*OPC?
1

All pending operations
are completed.

*RCL

Status Command

Description

The Recall Instrument State command restores the
instrument settings from a previously saved
memory setting.

Syntax

*RCL

Parameter

Recall Memory Setting

1~120

1~120

Example

*RCL 1

Recalls Setting memory 1

*RDT?

System Command

Description

Returns the load module type in each channel in
order from 1~8. If no frame is present a 0 is
returned.

Query Syntax

*RDT?

Return Parameter

Occupied Channel

2020L

PEL-2020 left channel

0

Empty channel

Query Example

*RDT?
0,0,2020L,2020R,0,0,0,0

Channels 1-2 and 5-8 are
empty; 3-4 is occupied
by the PEL-2020 load
module.

*RST

Status Command

Description

Resets the mainframe by forcing the ABORt, *CLS,
and LOAD:PROT:CLE command.

Syntax

*RST

Example

*RST