beautypg.com

Resistance:static:high:rise/fall – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 108

background image

PEL-2000 Programming Manual

108

Query Syntax

:RESistance:STATic:HIGH:AVALue/BVALue?
[MAX|MIN]

Return Parameter [MAX|MIN]

Resistance

1 unit= 1 ohm

Returns the resistance of
the A or B Value.

Query Example

:RES:STAT:HIGH:BVAL?
MAX
15000.0

Returns the maximum
resistance allowed for
the channel for B Value.
(PEL-2020)

:RESistance:STATic:HIGH:RISE/FALL

Channel Specific
Command

Description

Sets the high range rising/falling slew rate.

Syntax

:RESistance:STATic:HIGH:RISE/FALL [A/uS]

Parameter

[A/uS]

Slew rate

RISE/FALL 0.8A/uS

Sets the rising/falling slew
rate to 0.8A/uS

RISE/FALL 0..5

Sets the rising/falling slew
rate to 0.5A/uS

RISE/FALL MIN

Sets to the slowest
rising/falling slew rate.

RISE/FALL MAX

Sets to the fastest
rising/falling slew rate.

Example

:RES:STAT:HIGH:RISE 1.1

Sets the rising slew rate
to 1.1A/uS.

Query Syntax

:RESistance:STATic:HIGH:RISE/FALL? [MIN|MAX]

Return Parameter [MAX|MIN]

Slew rate

1 Unit=1 amp/uS

Returns the slew rate.

MAX/MIN

Returns the allowable
maximum and minimum.