beautypg.com

Configure:protection:uvp:level, Configure:response – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 48

background image

PEL-2000 Programming Manual

48

:CONFigure:PROTection:UVP:LEVel

Channel Specific
Command

Description

Sets the under voltage protection level for the
current/specific channel. The level can be set to
any applicable level or to the channel
maximum/minimum.

Syntax

:CONFigure:PROTection:UVP:LEVel
[W]|MIN|MAX

Parameter

UVP Level

20

20 Volts

20V

20 Volts

MIN

Sets to the minimum level
(OFF)

MAX

Sets the voltage limit to
the maximum level

Example

:CONF:PROT:UVP:LEV MIN

Sets the UVP limit to OFF

Query Syntax

:CONFigure:PROTection:UVP:LEVel? [MIN|MAX]

Return Parameter

Power protection level

1 unit = 1 volt

Returns the UVP level as
volts.

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:CONF:PROT:UVP:LEV?

75

UVP level is at 75 volts.

:CONFigure:RESPonse

Channel Specific
Command

Description

Sets or queries the response rate for the specific
channel.

Syntax

:CONFigure:RESPonse {NORMAL|0|FAST|1}

Parameter

NORMAL/0

Normal

FAST/1

Fast