beautypg.com

Sequence:point:current, Sequence:point:rise/fall – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 151

background image

COMMAND DETAILS

151

1 unit = 1 ohm

Returns the resistance
value.

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:SEQ:POIN:RES?
100

The resistance value is
100 ohm.

:SEQuence:POINt:CURRent

Channel Specific
Command

Description

Sets the current value for the current point. CC
mode only.

Syntax

:SEQuence:POINt:CURRent [A]|MIN|MAX

Parameter

[A], MIN, MAX

Current value

10

10A

100 A

100A

MAX/MIN

Maximum or minimum
value.

Example

:SEQ:POIN:CURR 1

Sets the current to 1.

Query Syntax

:SEQuence:POINt::CURRent? [MAX|MIN]

Return Parameter

Current Value

1 unit = 1 A

Returns the current value.

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:SEQ:POIN:CURR?
1

The current value is 1
amp.

:SEQuence:POINt:RISE/FALL

Channel Specific
Command

Description

Sets the rising and falling slew rates for the current
point.

Syntax

:SEQuence:POINt:RISE/FALL[A/us]|MIN|MAX

Parameter

[A/us], MIN, MAX Slew rate