beautypg.com

Configure:protection:power:state – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 46

background image

PEL-2000 Programming Manual

46

MIN

Sets to the minimum level

MAX

Sets the voltage limit to
the maximum level

Example

:CONF:PROT:VOLT:LEV MAX

Sets the voltage limit to
81.6V (PEL2020)

Query Syntax

: CONFigure:PROTection:VOLTage:LEVel? [MIN|MAX]

Return Parameter 1 unit = 1 volt

Voltage protection level

1.00

1.00 volts.

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:CONF:PROT:VOLT:LEV?
81.6000

Voltage protection level
is at 81.6V.

:CONFigure:PROTection:POWer:STATe

Channel Specific
Command

Description

Sets the power protection for the current/specific
channel on or off. The power protection can also be
cleared.

Syntax

:CONFigure:PROTection:POWer:STATe
{OFF|0|ON|1|CLEAR|2}

Parameter

CLEAR/2

Cleared

OFF/0

Off

ON/1

On

Example

:CONF:PROT:POW:STAT 1

Turns on power protection.

Query Syntax

: CONFigure:PROTection:POWer:STATe?

Return Parameter

Power Protection

0

Off

1

On

2

Clear

Query Example

:CONF:PROT:POW:STAT?

1

Power protection is
currently on.