Power:current – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 136

background image

PEL-2000 Programming Manual

136

1 unit = 1 watt

Returns the power of the A
Value (L1) or B Value (L2).

MAX/MIN

Returns the allowable
maximum and minimum.

Query Example

:POW:L2? MAX
357.000

Returns the maximum
power allowed for the
channel. (PEL-2040)

:POWer:CURRent

Channel Specific
Command

Description

Sets the current limit for constant power mode.
The command is range dependant. If the current
range is Low, then the command will only apply to
the low range settings.

Syntax

:POWer:CURRent [A]

Parameter

[A]

1

Sets the current limit to
1A.

1A

Sets the current limit to
1A.

MIN

Sets the current limit to
the minimum level for the
specific channel.

MAX

Sets the current limit to
the maximum level for the
specific channel.

Example

:POW:CURR 1

Sets the current limit to
1A.

Query Syntax

:POW:CURRent? [MAX|MIN]

Return Parameter [MAX|MIN]

Current

1 unit = 1 amp

Returns the current limit.

MAX/MIN

Returns the allowable
maximum and minimum.