beautypg.com

Fetch subsystem, Fetch:voltage, Fetch:current – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 71

background image

COMMAND DETAILS

71

FETCH Subsystem

:FETCh:VOLTage? .......................................................... 71

:FETCh:CURRent? ........................................................... 71

:FETCh:POWer? .............................................................. 72

:FETCh:STATus? ............................................................. 72

:FETCh:ALLVoltage? ....................................................... 72

:FETCh:ALLCurrent? ....................................................... 73

:FETCh:ALLPower? ......................................................... 73

:FETCh:VOLTage?

Channel Specific
Status Command

Description

This query returns the real-time voltage of the load
module input for the specific channel.

Syntax

:FETCh:VOLTage?

Parameter

1 unit = 1 volt

Voltage

8

8 volts

Query Example

:FETC:VOLT?
11.2

The specific channel has
a voltage of 11.2 volts at
the input.

:FETCh:CURRent?

Channel Specific
Status Command

Description

This query returns the real-time current of the load
module input for the specific channel.

Syntax

:FETCh:CURRent?

Parameter

1 unit= 1 amp

1

1 amp

Query Example

:FETC:CURR?
1.2

The specific channel has
a current of 1.2 amps at
the load module input.