beautypg.com

Current:static:high:rise/fall – GW Instek PEL-2000 Series Programming User Manual User Manual

Page 61

background image

COMMAND DETAILS

61

AVALue 10

Sets A Value to 10 Amps.
(high range only)

BVALue 20

Sets B Value to 20 Amps.
(high Range only)

AVALue MIN

Sets A Value to the
minimum level for the
specific channel.

A Value MAX

Sets A Value to the
maximum Level for the
specific channel.

Example

:CURRent:STATic:HIGH:AV
ALue 10

Sets high range CC static
mode A Value to 10
amps.

Query Syntax

:CURRent:STATic:HIGH:AVALue/BVALue? [MAX|MIN]

Return Parameter [MAX|MIN]

Auto load mode

MAX/MIN

Returns the allowable
maximum and minimum.

1 unit= 1 amp

Returns the current of the
A or B Value.

Query Example

:CURR:STAT:HIGH:BVALu
e? MAX
20.4000

Returns the maximum
current allowed for the
channel in high range
mode. (PEL-2020)

:CURRent:STATic:HIGH:RISE/FALL

Channel Specific
Command

Description

Sets the high range rising/falling slew rate.

Syntax

:CURRent:STATic:HIGH:RISE/FALL [A/uS]

Parameter

[A/uS]

Slew Rate

RISE/FALL 0.8A/uS

Sets the rising/falling slew
rate to 0.8A/uS

RISE/FALL 1

Sets the rising/falling slew
rate to 1A/uS