External i/o specifications, Npn specification, Caution – IAI America XSEL-QX User Manual
Page 62

38
Part 1 Installation
2. External I/O Specifications
2.1. NPN
Specification
(1) Input
part
External Input Specifications (NPN Specification)
Item
Specification
Input voltage
24 VDC
r10%
Input current
7 mA per circuit
ON/OFF voltage
ON voltage --- 16.0 VDC min.
OFF voltage --- 5.0 VDC max.
Insulation method
Photocoupler insulation
External devices
[1] No voltage contact (minimum load of approximately 5 VDC/1 mA)
[2] Photoelectric/proximity sensor (NPN type)
[3] Sequencer transistor output (open-collector type)
[4] Sequencer contact output (minimum load of approximately 5 VDC/1
mA)
[Input circuit]
* P24: I/O interface pin No. 1
Caution
If a non-contact circuit is connected externally, malfunction may result from leakage
current. Use a circuit in which leakage current in a switch-off state does not exceed 1
mA.
~ X-SEL controller’s input signal
At the default settings, the system recognizes the ON/OFF durations of input signals if they
are approximately 4 msec or longer. The ON/OFF duration settings can also be changed
using I/O parameter No. 20 (input filtering frequency).
Internal cir
cuit
Input terminal
External power supply
24 VDC
10%
ON duration
OFF duration
P24*
+
-
560
:
3.3 k
: