132
Part 4 Commands
Operation type in the output field
CC: Command was executed successfully, ZR: Operation result is zero,
PE:
Operation is complete, CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1
z Operand 2,
GT:
Operand 1 > Operand 2, GE: Operand 1
t Operand 2,
LT:
Operand 1 < Operand 2, LE: Operand 1
d Operand 2
Category
Condition Command
Operand 1
Operand 2
Output
Function
Page
Optional HOME
Home-return
axis
pattern Prohibited
PE
Return to home (Linear movement
axis only)
228
Optional SV
Operation axis pattern
Prohibited
PE
Servo [ON, OF]
229
Optional MOVP
Destination position
number
Prohibited
PE
Move to specified position
230
Optional MOVL
Destination position
number
Prohibited PE
Move to specified position via
interpolation
231
Optional
MVPI
Travel position number
Prohibited
PE
Move to relative position
232
Optional
MVLI
Travel position number
Prohibited
PE
Move to relative position via
interpolation
233
Optional PATH
Start
position number
End position number
PE
Move along path
234
Optional J
W
Axis operation pattern
Start I/O, flag
PE
Jog [FN, FF, BN, BF]
235
Optional
STOP
Axis stop pattern
Prohibited
CP
Decelerate and stop axis
237
Optional
PSPL
Start position number
End position number
PE
Move along spline
238
Optional
PUSH
Target position number
Prohibited
PE
Move by push motion
239
Optional CIR2
Passing position 1
number
Passing position 2
number
PE
Move along circle 2 (arc
interpolation)
241
Optional
ARC2
Passing position number
End position number
PE
Move along arc 2 (arc interpolation)
243
Optional CIRS
Passing position 1
number
Passing position 2
number
PE
Move three dimensionally along
circle
245
Optional ARCS
Passing position number
Passing position
number
PE
Move three dimensionally along arc
247
Optional
ARCD
End position number
Center angle [deg]
PE
Move along arc via specification of
end position and center angle
249
Optional
ARCC
Center position number
Center angle [deg]
PE
Move along arc via specification of
center position and center angle
251
Optional CHVL
Axis
pattern Speed
CP
Change speed (Linear movement
axis only)
253
Optional PBND
Axis
pattern Distance
CP
Set
positioning band 255
Optional
TMPI Position
number
Prohibited
PE
Move relatively between positions
on tool coordinate system (SCARA
only)
256
Optional
TMLI Position
number
Prohibited
PE
Move relatively between positions
on tool coordinate system via
interpolation (SCARA only)
257
Optional
PTRQ
Axis pattern
Ratio [%]
CC
Change push torque limit parameter
258
Optional CIR
Passing position 1
number
Passing position 2
number
PE
Move along circle (CIR2 is
recommended)
259
Optional ARC
Passing
position number
End position number
PE
Move along arc (ARC2 is
recommended)
260
Refer to the page on palletizing for commands relating to arch motion.
Optional
ARCH
Position number
Position number
PE
Arch motion
315
Optional ACHZ Axis
number
Prohibited
CP Declare arch motion Z-axis
305
Optional
ATRG
Position number
Position number
CP
Set arch trigger
306
Optional
AEXT
(Position number)
Prohibited
CP
Set arch motion composition
307
Actuator
control
command
Optional OFAZ Offset
value
Prohibited CP
Set
arch
motion Z-axis offset
307
Optional IF
Comparison variable
Comparison value
CP Compare
[EQ,
NE, GT, GE, LT, LE]
261
Optional IS
Column
number
Column number,
character literal
CP Compare
strings
262
Prohibited ELSE
Prohibited
Prohibited
CP
Declare execution destination when
IF command condition is not
satisfied
263
Structural
IF
Prohibited EDIF
Prohibited
Prohibited
CP
Declare end of IF
263
Optional DW
Comparison variable
Comparison value
CP Loop
[EQ,
NE,
GT, GE, LT, LE]
264
Optional
LEAV
Prohibited
Prohibited
CP
Pull out from DO
264
Optional ITER
Prohibited
Prohibited CP
Repeat
DO
265
Structural
DO
Prohibited EDDO
Prohibited
Prohibited
CP
Declare end of DO
265
Optional
SLCT
Prohibited
Prohibited
CP
Declare start of multi-branching
266
Prohibited WH
Comparison variable
Comparison value
CP
Branch value [EQ, NE, GT, GE, LT,
LE]
267
Prohibited WS
Column
number
Column number,
character literal
CP
Branch character string [EQ, NE]
268
Prohibited OTHE
Prohibited
Prohibited
CP
Declare branching destination when
condition is not satisfied
269
Multi-
branching
Prohibited EDSL
Prohibited
Prohibited
CP
Declare end of SLCT
269