513
Appendix
(In the pan
el wind
ow, the thre
e digits aft
er “E” in
dicate an erro
r nu
mber.
)
Error No.
Error name
Description, ac
tion, etc.
D58
Fieldbus error (
INIT
timeout)
An INIT
timeout
w
a
s detected.
Check the stat
us of the monit
o
r LED on the f
ront face of the board by
refer
ring to the
oper
ation manual for
your fiel
d
net
w
o
rk.
D59
Fieldbus error (
D
PRAM
w
rite/r
ead)
A DPRAM
w
rite/read err
or
w
a
s detected.
Check the stat
us of the monit
o
r LED on the f
ront face of the board by
refer
ring to the
oper
ation manual for
your fiel
d
net
w
o
rk.
D5A
Fieldbus error (
T
OGGLE time
out)
A
T
O
GGLE timeout
w
a
s detec
ted.
Check the stat
us of the monit
o
r LED on the f
ront face of the board by
refer
ring to the
oper
ation manual for
your fiel
d
net
w
o
rk.
D5B
Fieldbus error (
A
ccess-privi
lege retr
y
ov
er)
An access-priv
ilege r
e
tr
y
ov
er error
w
a
s det
ected.
Check the stat
us of the monit
o
r LED on the f
ront face of the board by
refer
ring to the
oper
ation manual for
your fiel
d
net
w
o
rk.
D5C
Fieldbus error (
A
ccess-privi
lege open error)
An access-priv
ilege
open error
w
a
s detected.
Check the stat
us of the monit
o
r LED on the f
ront face of the board by
refer
ring to the
oper
ation manual for
your fiel
d
net
w
o
rk.
D5D
Fieldbus error (
F
BRS link error)
A FBRS link error
w
a
s detect
ed.
Check the stat
us of the monit
o
r LED on the f
ront face of the board by
refer
ring to the
oper
ation manual for
your fiel
d
net
w
o
rk.
D5E
Fieldbus error (
Mailbox
response)
A mailbox
res
ponse err
or
w
a
s
detected.
Check the stat
us of the monit
o
r LED on the f
ront face of the board by
refer
ring to the
oper
ation manual for
your fiel
d
net
w
o
rk.
D60
Expanded-SIO
2/4 CH insulati
on po
w
e
r error
An Ex
pan
de
d-SIO insulatio
n po
w
e
r
error
w
a
s detected.
D61
Expanded-SIO
1/3 CH insulati
on po
w
e
r error
An Expan
de
d-SIO insulatio
n po
w
e
r
error
w
a
s detected.
D62
Expanded-SIO
baud-r
ate-generator clock os
cillati
on error
An Expan
de
d-SIO clock oscill
ation err
or
w
a
s
detected.
D63
Expanded-SIO
UART
paging
error
An Expan
ded-SIO paging err
or
w
a
s detected.
D64
Ex
panded-SIO
assignm
ent er
ror
T
he “board channel
assignment number” or “
e
xpanded-I/O
slot assignment number”
in I/O parameter Nos. 100, 102, 104, 1
06, 108 or 110 may
be outside the input
range or duplic
ated, a serial communic
ation expa
nsion board may
not be i
n
stalled in
the specifi
ed sl
ot, or a “communication mo
de
” other than RS
232C m
a
y
hav
e bee
n
selected
w
h
en the “boar
d channel
assignm
ent number” is other than “1” or
“2,”
among other reasons.