Alphabetical order – IAI America XSEL-QX User Manual
Page 160
136
Part 4 Commands
2. Alphabetical
Order
Operation type in the output field
CC:
Command was executed successfully,
ZR:
Operation result is zero, PE: Operation is complete,
CP:
Command part has passed, TU: Time up
EQ:
Operand 1 = Operand 2, NE: Operand 1
z Operand 2,
GT:
Operand 1 > Operand 2, GE: Operand 1
t Operand 2,
LT:
Operand 1 < Operand 2, LE: Operand 1
d Operand 2
Command Page Condition
Operand 1
Operand 2
Output
Function
A
ABPG
174
Optional
Stop program number
(Stop program number)
CC
Stop other program
ACC
195
Optional
Acceleration
Prohibited
CP
Set acceleration
ACCS 196
Optional
Ratio
[%]
Prohibited
CP
Set acceleration ratio in PTP operation
(SCARA only)
ACHZ
305
Optional
Axis number Prohibited
CP
Declare arch motion Z-axis
ADD
143
Optional
Augend variable
Addend
ZR
Add
AEXT
307
Optional
(Position number)
Prohibited
CP
Set arch motion composition (SCARA only)
AND
151
Optional
AND operand variable
Operand
ZR
Logical AND
ARC
260
Optional
Passing position number End position number PE
Move
along
arc
ARC2
243
Optional
Passing position number End position number
PE
Move along arc 2
ARCC
251
Optional
Center position number
Center angle
PE
Move along arc via specification of center
position and center angle
ARCD
249
Optional
End position number
Center angle
PE
Move along arc via specification of end
position and center angle
ARCH
315
Optional
Position number
Position number
PE
Arch motion
ARCS
247
Optional
Passing position number Passing position number
PE Move
along
arc three-dimensionally
ATN
149
Optional
Inverse tangent
assignment operation
Operand ZR
Inverse
tangent
ATRG
306
Optional
Position number
Position number
CP
Set arch trigger
AXST
270
Optional
Variable number
Axis number
CP
Get axis status
B
BASE
204
Optional
Reference axis number
Prohibited
CP
Set reference axis
BGPA
293
Optional
Palletizing number
Prohibited
CP
Declare start of palletizing setting
BGSR
170
Prohibited
Declaration subroutine
number
Prohibited CP
Start
subroutine
BTPF
160
Optional
Output port, flag
Timer setting
CP
Output OFF pulse
BTPN
159
Optional
Output port, flag
Timer setting
CP
Output ON pulse
BT
158
Optional
Start output, flag
(End output, flag)
CP
Output, flag [ON, OF, NT]
C
CANC
207
Optional
(Input port to abort)
(CANC type)
CP
Declare port to abort
CHPR
317
Optional
0 or 1
Prohibited
CP
Change task level
CHVL
253
Optional
Axis pattern
Speed
CP
Change speed (Linear movement axis only)
CIR
259
Optional
Passing position 1
number
Passing position 2
number
PE Move
along
circle
CIR2
241
Optional
Passing position 1
number
Passing position 2
number
PE
Move along circle 2
CIRS
245
Optional
Passing position 1
number
Passing position 2
number
PE
Move three dimensionally along circle
CLOS
278
Optional
Channel number
Prohibited
CP
Close channel
CLR
142
Optional
Start of clear variable
End-of-clear variable
ZR
Clear variable
COS
147
Optional
Cosine assignment
variable
Operand ZR
Cosine
CP
154
Optional
Comparison variable
Comparison value
EQ NE GT
GE LT LE
Compare
D
DCL 197
Optional
Deceleration
Prohibited
CP
Set
deceleration
DCLS 198
Optional
Ratio
[%]
Prohibited
CP
Set acceleration ratio in PTP operation
(SCARA only)
DEG
203
Optional
Division angle
Prohibited
CP
Set division angle
DFIF 223
Optional
Interference check zone
number
Psition number
CP
Define coordinates of simple interference
check zone (SCARA only)
DFTL 221
Optional
Tool coordinate system
number
Psition number
CP
Define tool coordinate system (SCARA only)
DFWK 214
Optional
Load coordinate system
number
Psition number
CP
Define load coordinate system (SCARA only)
DIS
208
Optional
Distance
Prohibited
CP
Set spline division distance
DIV
144
Optional
Dividend variable
Divisor
ZR
Divide
DW
264
Optional
Comparison variable
Comparison value
CP
Loop [EQ, NE, GT, GE, LT, LE]