IAI America XSEL-QX User Manual
Page 103
79
Part 1 Installation
2.2 PNP
specification
Pin No. Category Port No.
Function (factory setting)
1 -
+24-V input
2 000
Program start
3 001
General-purpose input
4 002
General-purpose input
5 003
General-purpose input
6 004
General-purpose input
7 005
General-purpose input
8 006
General-purpose input
9
007
Program specification (PRG No. 1)
10
008
Program specification (PRG No. 2)
11
009
Program specification (PRG No. 4)
12
010
Program specification (PRG No. 8)
13
011
Program specification (PRG No. 10)
14
012
Program specification (PRG No. 20)
15
013
Program specification (PRG No. 40)
16 014
General-purpose input
17
015
General-purpose input
18 016
General-purpose input
19 017
General-purpose input
20 018
General-purpose input
21 019
General-purpose input
22 020
General-purpose input
23 021
General-purpose input
24 022
General-purpose input
25
023
General-purpose input
26 024
General-purpose input
27 025
General-purpose input
28 026
General-purpose input
29 027
General-purpose input
30 028
General-purpose input
31 029
General-purpose input
32 030
General-purpose input
33
Input
031
General-purpose input
34 300
Alarm output
35 301
Ready output
36 302
Emergency-stop
output
37 303
General-purpose output
38 304
General-purpose output
39 305
General-purpose output
40 306
General-purpose output
41 307
General-purpose output
42 308
General-purpose output
43 309
General-purpose output
44 310
General-purpose output
45 311
General-purpose output
46 312
General-purpose output
47 313
General-purpose output
48 314
Alarm output for low system-memory backup
battery voltage
49 315
Alarm output for low absolute-encoder backup
battery voltage
50
Output
- 0
V
Connect +24 V to pin No. 1 and 0 V to pin No. 50.
0 V
+24 V
Digital switch