IAI America XSEL-QX User Manual
Page 319

295
Part 4 Commands
z PASE (Declare palletizing axes)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PASE
Axis
number
Axis
number
CP
Set the two axes to be used in palletizing (PX and PY-axes).
The axis specified in operand 1 will be set as the preferential axis (PX-axis).
The axis specified in operand 2 will be set as the PY-axis.
This command is used in conjunction with PAPT and PAST.
It cannot be used together with a 3-point teaching (PAPS) command. Whichever is set later will be given
priority.
It is recommended to use a 3-point teaching (PAPS) command if the palletizing requires high precision.
If this command is executed before BGPA is declared (= while palletizing setting is not enabled), an error
will generate.
If the output field is specified, the output will turn ON after this command is executed.
Do not use any palletizing setting involving both SCARA and linear movement axes.
If the palletizing setting involves both SCARA and linear movement axes, an “Error No. 421,
SCARA/linear movement axis simultaneous specification error” will generate.
z PAPT (Set palletizing pitches)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PAPT Pitch Pitch
CP
Set palletizing pitches.
The value specified in operand 1 will be set as the pitch for the preferential axis (PX-axis), while the
value specified in operand 2 will be set as the pitch for the PY-axis.
This command is used in conjunction with PASE and PAST.
If this command is executed before BGPA is declared (= while palletizing setting is not enabled), an error
will generate.
If the output field is specified, the output will turn ON after this command is executed.