IAI America XSEL-QX User Manual
Page 186

162
Part 4 Commands
z IN (Read I/O, flag as binary)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional
Optional
IN
I/O, flag
I/O, flag
CC
[Function]
Read the I/O ports or flags from the one specified in operand 1 through the other specified
in operand 2, to variable 99 as a binary.
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
Binary
15 14 13 12 11 10 9 8
Input port number
ON OFF OFF OFF
OFF
ON
OFF
ON
1 0 0 0 0 1 0 1
Binary
2
7
+ 0 + 0 + 0 + 0 + 2
2
+ 0 + 2
0
128
+ 0 + 0 + 0 + 0 + 4 + 0 + 1
= 133
133
Variable 99
(Note 1)
A maximum of 32 bits can be input.
(Note 2)
When 32 bits have been input and the most significant bit is ON, the value read to variable
99 will be treated as a negative value.
(Note 3)
The data format used for read can be changed using a FMIO command (refer to the
explanation of the FMIO command).
[Example 1]
IN
8
15
Read input ports 8 through 15, to variable 99 as a
binary.
[Example 2]
LET
1
8
Assign 8 to variable 1.
LET
2
15
Assign 15 to variable 2.
IN
*1
*2
Read the input ports from the content of variable 1
(input port 8) through the content of variable 2 (input
port 15), to variable 99 as a binary.