Multipoint dio board, Overview, Board variations – IAI America XSEL-QX User Manual
Page 105: Specifications
81
Part 1 Installation
3. Multipoint DIO Board
This board is a multipoint DIO board for XSEL controllers on which 48 input points and 48 output points
are provided.
3.1 Overview
3.1.1 Features
[1] 96 points can be input/output using a single board.
One board provides 48 input points and 48 output points to enable multipoint I/O control with your
XSEL controller.
[2] PNP/NPN DIO interfaces are supported.
As with other current IO boards, two types of DIO interfaces–NPN and PNP–are available.
[3] Overcurrent & I/O power monitor functions
The DO board is monitored for overcurrent and IO power-supply voltage and if an overcurrent is
detected or the specified voltage is exceeded, DO outputs are cut off. Take note, however, that unlike
with current IO boards, the overcurrent detection is performed based on 400 mA/24 points. (Current
IO boards: 400 mA/8 points)
3.1.2 Board
Variations
This board is available in the variations shown in the table below.
Model
IA-IO-3204-NP
General-purpose, large-capacity XSEL
multipoint I/O board (NPN specification)
IA-IO-3204-NP
General-purpose, large-capacity XSEL
multipoint I/O board (PNP specification)
3.2 Specifications
3.2.1 I/O
Specifications
Item Specification
Number of I/O points
48 input points, 48 output points
External power-supply voltage
DC 24 V
r 10%
Input insulation
Photocoupler insulation
Input current
Max. 7 mA/1 point
Input leak current
Max. 7 mA/1 point
Output insulation
Photocoupler insulation
Output element
Transistor
Maximum output load current
50 mA/1 point (400 mA/24 points)
Output leak current
Max. 0.1 mA/1 point