IAI America XSEL-QX User Manual
Page 437

413
Appendix
(3) Parameter Settings
The SIO channel numbers and specifications are set as follows according to the factory-set parameters.
For advanced settings, set the following parameters sequentially:
Channel 1
o I/O parameter Nos. 201 to 203
Channel 2
o I/O parameter Nos. 213 to 215
I/O Parameter Settings (Reference)
No.
Parameter name
Default value
Input range
Unit
201
Attribute 1 of SIO channel 1 opened to user
(mount standard)
28100001H
0H to FFFFFFFFH
None
213
Attribute 2 of SIO channel 1 opened to user
(mount standard)
28100001H
0H to FFFFFFFFH
None
Bits 28 to 31:
Baud rate type (0: 9.6, 1: 19.2, 2: 38.4, 3: 57.6, 4: 76.8, 5: 115.2 kbps)
Bits 24 to 27:
Data length (7 or 8)
Bits 20 to 23:
Stop bit length (1 or 2)
Bits 16 to 19:
Parity type (0: None, 1: Odd, 2: Even)
Bits 12 to 15:
For future extension
Bits 8 to 11:
For future extension
Bits 4 to 7:
For future extension
Bits 0 to 3:
Use selection (0: Do not use, 1: Use)
Channel 1
Specifications
Baud rate: 38.4 kbps
Data length: 8
Stop bit: 1
Parity type: None
Communication mode: RS232
Baud rate
0: 9.6 kbps 1: 19.2 kbps 2: 38.4 kbps 3: 57.6 kbps 4: 76.8 kbps 5: 115.2 kbps
Data length: 7, 8
Stop bit length: 1, 2
Parity type: 0: None, 1: Odd, 2: Even
For future extension
For future extension
For future extension
Use selection: 0 (Do not use, 1: Use)
Channel 2