IAI America XSEL-QX User Manual
Page 471

447
Appendix
Parameters Common to All Axes
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
204 Maximum
deceleration
of linear movement axis
100
1 ~ 999
0.01 G
* Valid for linear movement axes (axes 5 and 6 (6-axis
type)) only.
(Main application version 0.12 or later)
205 Minimum
emergency
deceleration of linear
movement axis
30
1 ~ 300
0.01 G
* Valid for linear movement axes (axes 5 and 6 (6-axis
type)) only.
(Main application version 0.12 or later)
206 Safety speed of linear
movement axis in
manual mode
250
1 ~ 250
mm/s
* Handled as a value equal to or below the smallest
value of “Axis-specific parameter No. 29, VLMX
speed of linear movement axis” applicable to all valid
linear movement axes.
* Valid for linear movement axes (axes 5 and 6 (6-axis
type)) only.
(Main application version 0.12 or later)
207~
300
(For extension)
~
301~
400
(For extension)
~
(Main application version 0.65 or later/controller with
increased memory size (with gateway function) only)
PC: PC
software
TP: Teaching
pendant