IAI America XSEL-QX User Manual
Page 457

433
Appendix
I/O Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
60 Output function selection 314
1
0 ~ 5
0: General-purpose output
1: Absolute-data backup battery voltage-low warning
level or lower (OR check of all axes. Upon detection of
abnormal level, the output will be latched until a
power-ON reset or software reset is executed.)
61 Output function selection 315
0
0 ~ 5
0: General-purpose output
62 For
future
extension
(Change prohibited)
0
0 ~ 299
63 For
future
extension
(Change prohibited)
0
0 ~ 299
64 Physical input port number
for axis-3 brake forced
release
0 0
~
299
Forcibly unlock the brake when the applicable port is ON
(be aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is
specified)
* The synchro slave axis will follow the synchro master
axis.
65 Physical input port number
for axis-4 brake forced
release
0 0
~
299
Forcibly unlock the brake when the applicable port is ON
(be ware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is
specified)
* The synchro slave axis will follow the synchro master
axis.
66 Physical input port number
for axis-5 brake forced
release
0 0
~
299
Forcibly unlock the brake when the applicable port is ON
(be ware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is
specified)
* Valid only for the 6-axis type.
67 Physical input port number
for axis-6 brake forced
release
0 0
~
299
Forcibly unlock the brake when the applicable port is ON
(be ware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is
specified)
* Valid only for the 6-axis type.
68~
69
(For extension)
0
70 Unaffected
general-purpose
output area number (MIN)
when all operations/
programs are aborted
0 0
~
599
* Important: Outputs in this area must be operated under
the responsibility of user programs including the “I/O
processing program at operation/program abort.”
Outputs outside this area will be forcibly turned OFF.
(Invalid if “0” is set)
71 Unaffected
general-purpose
output area number (MAX)
when all
operations/programs are
aborted
0 0
~
599
72 Unaffected
general-
purpose output area
number (MIN) when all
operations are paused
(servo-axis soft interlock +
output-port soft interlock)
300
0 ~ 599
* Important: Outputs in this area must be operated
(including recovery) under the responsibility of user
programs including the “I/O processing program at
all operations pause.” Outputs outside this area will
be forcibly turned OFF, reflecting/holding the results
of operations performed while all operation pause is
effective (only during automatic operation). (Invalid
if “0” is set)
73 Unaffected
general-
purpose output area
number (MAX) when all
operations are paused
(servo-axis soft interlock +
output-port soft interlock)
599
0 ~ 599
74 Number of TP user output
ports used (hand, etc.)
0
0 ~ 8
Referenced by TP.
(Invalid if “0” is set)
75 TP user output port start
number (hand, etc.)
0
0 ~ 599
Referenced by TP.
76 AUTO-mode
physical
output port number
0
0 ~ 599
(Invalid if “0” is set)
77 Input port number for
acceptance permission of
PC/TP servo movement
command
0
0 ~ 299
* Important: Invalid after operation has started.
(Invalid if “0” is set)