Chapter 9 maintenance, Chapter 9, Maintenance – IAI America XSEL-QX User Manual
Page 117: Inspection points

93
Part 1 Installation
Chapter 9 Maintenance
x Routine maintenance and inspection are necessary so that the system will operate properly at all times.
Be sure to turn off the power before performing maintenance or inspection.
x The standard inspection interval is six months to one year. If the environment is adverse, however, the
interval should be shortened.
1. Inspection
Points
x Check to see if the supply voltage to the controller is inside the specified range.
x Inspect the ventilation holes in the controller and remove dirt, dust and other foreign objects, if any.
x Inspect the controller cables (controller o actuator) and check for any loose screws or cable
disconnection.
x Check the controller mounting screws, etc., for looseness.
x Inspect each cable (axis link cable, general purpose I/O cable, system I/O cable, power cable) for
loose connection, disconnection, play, etc.