11 spi controller, Tmp92cz26a, 25 pf – Toshiba H1 Series User Manual
Page 666

TMP92CZ26A
92CZ26A-663
4.3.11 SPI
Controller
Variable
Parameter Symbol
Min Max
80MHz 60 MHz
Unit
SPCLK frequency (
= 1/S)
f
PP
20
20 15
MHz
SPCLK rising time
t
r
6
6
6
SPCLK falling time
t
f
6
6
6
SPCLK low width
t
WL
0.5S
− 6
19
28
SPCLK high width
t
WH
0.5S
−
6 19
28
Output data valid
→ SPCLK rising
t
ODS
0.5S
− 18
7
15
SPCLK rising/ falling
→ Output data hold
t
ODH
0.5S
− 10
15
23.4
Input data valid
→ SPCLK rising/ falling
t
IDS
5
5
5
SPCLK rising/ falling
→ Input data valid
t
IDH
5
5
5
ns
AC measuring condition
• Clock of top column in above table shows system clock frequency, and “S” in “Variable” show
SPCLK clock cycle [ns].
• C
L
= 25 pF
SPCLK Output
(at SPIMD
= “11”)
SPDO Output
f
PP
t
r
t
f
0.2V
CC
0.7 V
CC
t
WL
t
WH
t
ODS
t
ODH
t
IDS
t
IDH
SPDI Input
SPCLK Output
(at SPIMD
= “00”)