Epx_full_a/b, Epx_empty_a/b – Toshiba H1 Series User Manual
Page 376

TMP92CZ26A
92CZ26A-373
7 6 5 4 3 2 1 0
bit Symbol
EP1_FULL_A EP1_Empty_A
EP1_FULL_B
EP1_Empty_B
EP2_FULL_A
EP2_Empty_A EP2_FULL_B EP2_Empty_B
Read/Write
R/W R/W R/W R/W R/W R/W R/W R/W
After
reset
0 0 0 0 0 0 0 0
Function
When read 0: Not generate interrupt
1: Generate interrupt
When write 0: Clear flag
1:
−
Note: Above interrupt can release Halt state from IDLE2 mode. (IDLE1 and STOP mode can not be released.)
7 6 5 4 3 2 1 0
bit Symbol
EP3_FULL_A EP3_Empty_A EP3_FULL_B
EP3_Empty_B
Read/Write R/W R/W R/W R/W
After reset
0
0
0
0
Function
When read
0: Not generate interrupt
1:
Generate
interrupt
When write
0: Clear flag
1:
−
Note: Above interrupt can release Halt state from IDLE2 mode. (IDLE1 and STOP mode can not be released.)
•
EPx_FULL_A/B:
(When transmitting)
This is set to “1” when CPU full write data to FIFO_A/B.
(When receiving)
This is set to “1” when UDC full receive data to FIFO_A/B.
•
EPx_Empty_A/B:
(When transmitting)
This is set to “1” when FIFO become empty after transmission.
(When receiving)
This is set to “1” when FIFO become empty after CPU read all data from FIFO.
Note: The flag of EPx_FULL_A/B and EPx_Empty_A/B are not status flag. Therefore, check DATASET
register if the FIFO-status is needed.
USBINTFR2
(07F1H)
Prohibit
to read
modify
write
USBINTFR3
(07F2H)
Prohibit
to read
modify
write