6 timer input pulse (ta0in, ta2in, tb0in0, tb1in0), 7 interrupt operation, 8 usb timing (full-speed) – Toshiba H1 Series User Manual
Page 663: Tmp92cz26a

TMP92CZ26A
92CZ26A-660
4.3.6
Timer input pulse (TA0IN, TA2IN, TB0IN0, TB1IN0)
Variable
Parameter Symbol
Min Max
80 MHz 60 MHz Unit
Clock cycle
t
VCK
8T+100
200
234
Low level pulse width
t
VCKL
4T
+ 40
90
107
High level pulse width
t
VCKH
4T
+ 40
90
107
ns
4.3.7 Interrupt
Operation
Variable
Parameter Symbol
Min Max
80 MHz 60 MHz Unit
INT0~INT7 low width
t
INTAL
2T
+ 40
65
74
INT0~INT7 high width
t
INTAH
2T
+ 40
65
74
ns
4.3.8 USB
Timing
(Full-speed)
V
CC
= 3.3 ± 0.3 V/f
USB
= 48 MHz/Ta = 0 ~ 70°C
Parameter Symbol
Min
Max
Unit
D
+, D− rising time
t
R
4 20
D
+, D− falling time
t
F
4 20
ns
Output signal crossover voltage
V
CRS
1.3 2.0
V
AC measuring condition
D
+
D
−
TMP92CZ26A
R1 = 27
Ω
R1 = 27
Ω
R2 = 15 k
Ω
CL = 50 pF
R3 = 1.5 k
Ω
V
CC
Measuring
positoin
D
+, D−
V
CRS
90%
90%
10%
10%
t
R
t
F