Disappearing boot ROM
After boot sequence in BOOT mode, an application system program may continue to run
without reset asserting. In this case, an external memory which is mapped 3FE000H to
3FFFFFH address can not be accessed because of boot ROM is assigned.
To solve it, internal boot ROM can be disappered by setting BROMCR
“1”.
This
is initialized to “1”.
If this bit has been set to “1”, writing “0” is disabled.
7 6 5 4 3 2 1 0
Bit
symbol
CSDIS
ROMLESS
VACE
BROMCR
(016CH)
Read/Write
R/W
After Reset
1
0/1 (note)
1/0 (note)
Function
Nand_Flash
area
CS output
0: Enable
1: Disable
Boot ROM
0: use
1: not use
Vector
address
conversion
0: Disable
1: Enable