beautypg.com

Variables – IBM SC30-3865-04 User Manual

Page 453

background image

IPV6>traceroute

Destination IPv6 address []? 7::8

Source IPV6 address []? 6::9

Data size in bytes [56]?

Number of probes per hop [3]?

Wait time between retries in seconds [3]?

Maximum TTL [32]?

TRACEROUTE6 7::8: 56 data bytes

1 * * * *

IPV6>

See “Traceroute6” on page 402 for a description of the parameters.

Variables

Use the variables command to display information about the PIM configuration
variables.

Syntax:

variables

Example:

PIM6>v

PIM: on

Graft Timeout:

3 seconds

Assert Timeout:

210 seconds

PIM Unicast Metric Preferences (hex)

RIP

FFFF

Default

FFFF

Direct

FFFF

Fixed

FFFF

Filter

FFFF

PIM6>

PIM: on/off

This indicates whether PIM-DM is currently enabled or disabled.

Graft Timeout

The number of seconds that grafts are retransmitted if no graft
acknowledgement has been received.

Assert Timeout

The number of seconds that assert information learned by upstream routers
is retained before reverting back to local routing information.

PIM Unicast Metric Preferences

Displays current configured routing type metric preferences. Each route
type supported is listed with a hex value displaying the currently configured
metric preference.

PIM Monitoring Commands (Talk 5)

Chapter 16. Configuring and Monitoring Protocol Independent Multicast Routing Protocol (PIM)

423

|
|
|
|
|
|
|
|
|
|

|

|

|
|

|

|

|

|
|
|
|
|
|
|
|
|
|
|
|
|

|
|

|
|
|

|
|
|

|
|
|
|
|