Table 21. Configuration Parameter List - Port default LLC Characteristics (continued)

Parameter Information

Parameter

Inactivity timer (Ti)

Valid Values

1 to 254 seconds

Default Value

30 seconds

Description

This parameter specifies the LLC inactivity timer (Ti) for all link stations on this port.

An LLC link station uses Ti to detect an inoperative condition in either the remote link
station or in the transmission media. If an LPDU is not received in the time interval
specified by Ti, an S-format command LPDU with the poll bit set is transmitted to solicit
remote link station status. Recovery is then based on the reply timer (T1).

Parameter

Reply timer (T1)

Valid Values

1 to 254 half-seconds

Default Value

2 half-seconds

Description

This parameter specifies the LLC reply timer (T1) for all link stations on this port.

An LLC link station uses T1 to detect a failure to receive a required acknowledgment or
response from the remote link station. When T1 expires, the link station sends an
S-format command link layer protocol data unit (LPDU) with the poll bit set to solicit
remote link station status or any U-format command LPDUs that have not been
responded to. The duration of T1 should take into account any delays introduced by
underlying layers.

Parameter

Maximum number of retransmissions (N2)

Valid Values

1 to 254

Default Value

8

Description

This parameter specifies the maximum number of retransmissions (N2) for all link
stations on this port.

The N2 parameter specifies the maximum number of times an LPDU will be
retransmitted following expiration of the reply timer (T1).

APPN Configuration Commands

Chapter 2. Configuring and Monitoring APPN