7-176

SYSTEM SETTINGS►SYSTEM SETTINGS

Common Functions

Auto Colour Calibration (for Copy)

Auto Colour Calibration (for Print)

Copy Calibration by Screen

Printer Calibration by Screen

Performs automatic colour correction when the colour is off.
For copying, adjust with [Auto Colour Calibration (for Copy)]. For printing, adjust with [Auto Colour Calibration (for Print)].
You can use [Copy Calibration by Screen] and [Printer Calibration by Screen] to perform even higher precision
adjustment of each mode.
The machine prints a test patch, the test patch is scanned, and the colour is automatically corrected.
After the [Execute] key is tapped and a test patch is printed, a message appears prompting you to begin automatic
calibration.
Follow the instructions in the message to perform colour adjustment.

Density Smoothing Adjustment

If uneven density occurs in a copy and others, use this function to smooth the density.
The uneven density is automatically corrected by scanning a test patch that you print.
After the [Execute] key is tapped and a test patch is printed, a message appears prompting you to begin automatic
adjustment.
Follow the instructions in the message to perform density smoothing.
If there are no problems after adjustment, perform "Auto Colour Calibration (for Copy)" and "Auto Colour Calibration (for
Print)".
To return the adjusted values to their factory default state, tap [Return Density Smoothing Adjustment Value to Defaults].
If you tapped [Return to the Defaults], perform adjustment of the density that you want to readjust (medium density in the
default mode).

Remove Toner Cartridge

Normally toner cartridges cannot be removed. However, when a cartridge runs out of toner, the cartridge is
automatically ejected to allow removal. If you need to remove a cartridge that still has toner, you can manually eject and
remove the cartridge.
Select the toner cartridge to be ejected and tap the [Execute] key. The selected cartridge is ejected to allow removal.

• Before executing Auto Colour Calibration, check to see if the registration adjustment is correct.

If the registration adjustment is not correct, perform "Registration Adjustment."

• If the colour is still off after performing Auto Colour Calibration, repeating Auto Colour Calibration once again may improve

the colour.

If the intensity deviation correction does not resolve the intensity deviations, repeat the correction. This may suppress the
deviations.
To repeat the correction, start over the procedure from the first step, or tap the [Back] key after going through the correction
procedure.

To remove the toner cartridge, use the operation panel on the machine. You cannot perform the cartridge removal operation
on the web screen.