Embedded application settings -119, Polling setting -119, Embedded application settings – Sharp MX-6070N User Manual
Page 834: Polling setting, Install embedded application, Store embedded application, Delete embedded application
7-119
SYSTEM SETTINGS►SYSTEM SETTINGS
Embedded Application Settings
Store and manage “embedded applications” that are installed in the machine.
• [Add] key
Adds a new embedded application.
• List
Lists the currently installed embedded applications.
Install Embedded Application
When you tap the [Add] key, the registration screen appears. Up to 16 items can be installed.
Store Embedded Application
By storing an already installed embedded application in “standard application”, the application can be used. Select the
application name checkbox and tap the [Add Standard Applications] key.
Delete Embedded Application
Tap an application name in the list to display the information of that standard application.
After checking the information, delete the standard application with the [Delete] key.
Polling Setting
When linked to an external application, you can store and manage addresses in order to use a service that uses a polling function.
Address for Web Service
Enter the URL of the server or computer which sends commands and events by XML/SOAP protocol.
Timeout
Enter a timeout. The default setting is 20 seconds.
Browser
Select the Web browser type.
Extended Platform
Set this option to use the expansion platform.
Data Size
Set the screen size of application.
Cache User Information
Select the cache period of user information when offline mode is enabled. For information
on offline mode, consult your service technician.
E-mail Address
Enter the address to which a notification e-mail is sent when an application connection error occurs.
Body Text
Enter the body message that appears in the notification e-mail for connection errors.
• When installing from the operation panel of the machine, the files in the USB memory connected to the machine are
installed. When installing from the Web page, the files in the computer are installed.
• The maximum area of the hard disk that applications can use is 2 GB. If previously installed applications are already using
2 GB of area, a new application cannot be installed.
Item
Settings
Server 1 - Server 2
Set to enable each of the servers.
Polling Address
Enter the URL of the server or computer that the machine will poll.
Check Interval
Enter the check interval for the server. The default is 1 minute.
Timeout
Set the timeout time. The default setting is 20 seconds.
Item
Settings