Receiving application setting -118, External accounting application settings -118, Receiving application setting – Sharp MX-6070N User Manual
Page 833: External accounting application settings, Settings
7-118
SYSTEM SETTINGS►SYSTEM SETTINGS
Settings
* These functions can be set only in the Web page.
Receiving Application Setting
The Fax or I-Fax Receive functions can be set in the Sharp OSA applications.
Settings
External Accounting Application Settings
An external account application can be added and controlled.
Set the server name where you have installed the external accounting application.
Item
Settings
Application Name
Enter an application name.
Address for Application UI
Set an IP address of the application or a network name to control the UI of the machine.
Timeout
Enter a timeout. The default setting is 20 seconds.
Browser
Select the Web browser type.
Extended Platform
Set this option to use the expansion platform.
Data Size
Set the screen size of application.
Use Custom Icon*
Select whether or not custom icon is used.
File Name*
Reports file name.
Select File*
Please enter File Name.
Item
Settings
Forward to Application
The Fax or I-Fax message reception can be controlled by Sharp OSA applications.
Application Name
Enter the application name to receive.
Address for Web Service
Enter the Web service address.
Timeout
Enter a timeout. The default setting is 20 seconds.
E-mail Address
Enter the address to which a notification e-mail is sent when an application connection error occurs.
Body Text
Enter the body message that appears in the notification e-mail for connection errors.
Connection Test
To test the connection to the application, click the [Execute] button.
Item
Settings
External Account Control
Enable the totalling function by the external accounting application.
If enabled, always enter the application name or Web service address.
Set Authentication Server (Server 1)
If the server is set, the external authentication mode is selected. Any access to the MFP is
controlled by the application that you set on this page. If set, always enter the application
name, application UI address, or Web service address of server 1.
If not set, the external totalling mode is selected.
Server 1-4
Set to enable each of the servers.
Application Name
Enter an application name.
Address for Application UI
Enter the URL of the login screen to be accessed first when the machine is turned on.