Operating the FSP Amplifier Using FlexWorks

97

Case 2: In 1 changes during motion

Figure 57: Interrupt Example – Output Chart Case 2

From the chart:

♦ The motor started moving after In 1 became true.
♦ As the motor target speed reached 400, output 1 was set to

ON as interrupt 0 was invoked as a result of its condition
(Target_velocity>=400) being met.

♦ In 1 became false.
♦ The motor was stopped at the emergency deceleration by the

interrupt service routine for interrupt 1.

♦ The program jumped to label 2.
♦ Output 1 was set OFF.

N

OTE

:

If both interrupts occur simultaneously, the interrupt of priority
0 will be handled as in case 1, and then the interrupt of priority
1 will be handled as in case 2. The program will then return to
label 2.