205

MOVE command

Example of MOVE command (600uu in 1000 ms), of axis 2 in
Sequential mode:
Format:

N As a m Id1 Id2 C1 C2 V1 V2 P1 P2 P3 P4
N

2 B

3 0 0 7 1 0 0 0 0 0 0

P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15

0 2 5 8 0 0 0 0 0 3 E

P16 S1 S2 CR

8 1

F

CR

Where:

A = 2

Axis number 2

m = B

Sequential mode

ID1 = 0; Id2= 0

Ignore message ID

C1 = 7; C2 = 1

Command operational code = 0x71

V1, V2 = 0

All the command arguments are specified by
numerical values, not by variables.

P1 – P8 =
00000258

0x258 = 600

P9 – P16 =
000003E8

0x3E8 = 1000

S1 = 1; S2 = F

0x100–

(0x2B+00+0x71+00+00+0x02+0
x58
+00+00+0x03+0xE8)=
0XFFFFFFFFFFFFFF1F

Since only the last two digits are
considered, S1S2 = 0x1F.