Table 23: extended output signal selection – Yaskawa FSP Amplifier FlexWorks User Manual
Page 238

Parameter Reference
238
8.7. Table 23: Extended Output Signal
The following outputs are used in the user program:
Table 23: Extended Output Signal Selection
Parameter
Digit
Place
Name
Setting
Description
Default
Setting
0 Disabled.
1
Outputs from the SO1 (CN1-25, 26)
output terminal.
2
Outputs from the SO2 (CN1-27, 28)
output terminal.
0
/COIN Signal
Mapping
3
Outputs from the SO3 (CN1-29, 30)
output terminal.
0: Disabled
1 Not
used.
—
—
—
2 Not
used.
—
—
—
Pn2D2
3 Not
used.
—
—
—
N
OTES
:
1. When more than one signal is allocated to the same output
circuit, data is output using OR logic.
2. Depending on the control mode, undetected signals are
treated as OFF. For example, in the speed control mode, the
/COIN signal is treated as OFF.
3. Types of /WARN signals: Overload and regenerative
overload.