beautypg.com

Shift – Yaskawa FSP Amplifier FlexWorks User Manual

Page 77

background image

Operating the FSP Amplifier Using FlexWorks

77

4.9.14.2. Shift

By applying a positive shift, the profile graph is shifted in the
negative direction along the master position axis. Conversely, by
applying a negative shift, the profile graph is shifted in the positive
direction along the master position axis.

Figure 47: Illustration of the Application of Shift

The shift is specified as an absolute distance from the origin of the
profile graph.
In the case of a cyclic profile, the next profile will be followed as it

was originally specified, unless a different shift is specified.

To apply a shift:

1. Set the value of the variable ECAM_Shift using the

SET_VAR command.

N

OTE

:

The size of the shift is not affected by scaling the master axis.